7,144 research outputs found

    Trace anomalies and the string-inspired definition of quantum-mechanical path integrals in curved space

    Get PDF
    We consider quantum-mechanical path integrals for non-linear sigma models on a circle defined by the string-inspired method of Strassler, where one considers periodic quantum fluctuations about a center-of-mass coordinate. In this approach one finds incorrect answers for the local trace anomalies of the corresponding nn-dimensional field theories in curved space. The quantum field theory approach to the quantum-mechanical path-integral, where quantum fluctuations are not periodic but vanish at the endpoints, yields the correct answers. We explain these results by a detailed analysis of general coordinate invariance in both methods. Both approaches can be derived from the same operator expression and the integrated trace anomalies in both schemes agree. In the string-inspired method the integrands are not invariant under general coordinate transformations and one is therefore not permitted to use Riemann normal coordinates.Comment: LaTeX, 12 pages, 17 figure

    Mid-infrared imaging- and spectro-polarimetric subarcsecond observations of NGC 1068

    Get PDF
    We present sub-arcsecond 7.5-13 μ\mum imaging- and spectro-polarimetric observations of NGC 1068 using CanariCam on the 10.4-m Gran Telescopio CANARIAS. At all wavelengths, we find: (1) A 90 ×\times 60 pc extended polarized feature in the northern ionization cone, with a uniform \sim44^{\circ} polarization angle. Its polarization arises from dust and gas emission in the ionization cone, heated by the active nucleus and jet, and further extinguished by aligned dust grains in the host galaxy. The polarization spectrum of the jet-molecular cloud interaction at \sim24 pc from the core is highly polarized, and does not show a silicate feature, suggesting that the dust grains are different from those in the interstellar medium. (2) A southern polarized feature at \sim9.6 pc from the core. Its polarization arises from a dust emission component extinguished by a large concentration of dust in the galaxy disc. We cannot distinguish between dust emission from magnetically aligned dust grains directly heated by the jet close to the core, and aligned dust grains in the dusty obscuring material surrounding the central engine. Silicate-like grains reproduce the polarized dust emission in this feature, suggesting different dust compositions in both ionization cones. (3) An upper limit of polarization degree of 0.3 per cent in the core. Based on our polarization model, the expected polarization of the obscuring dusty material is \lesssim0.1 per cent in the 8-13 μ\mum wavelength range. This low polarization may be arising from the passage of radiation through aligned dust grains in the shielded edges of the clumps.Comment: 17 pages, 10 figures, accepted for publication at MNRA

    Prevention and management of idiosyncratic drug-induced liver injury: Systematic review and meta-analysis of randomised clinical trials

    Get PDF
    Conducting randomised clinical trials (RCTs) in idiosyncratic drug-induced liver injury (DILI) is challenging. This systematic review aims to summarise the design and findings of RCTs in the prevention and management of idiosyncratic DILI. A systematic literature search up to January 31st, 2020 was performed. Recognised scales were used to assess methodological bias and quality of the studies. Quantitative and qualitative analyses were performed. Heterogeneity was assessed with I2 statistic. Overall, 22 RCTs were included: 12 on prevention (n = 2,471 patients) and 10 in management (n = 797) of DILI/non-acetaminophen DILI-related acute liver failure (ALF). Silymarin (eight studies), bicyclol (four), magnesium isoglycyrrhizinate (three), N-acetylcysteine (three), tiopronin (one), L-carnitine (one), and traditional Chinese medicines (two) were tested in the intervention arm, while control arm mostly received standard supportive care or placebo. Main efficacy criteria in the prevention RCTs was DILI incidence or peak of liver enzymes value. In management RCTs, the efficacy parameter was usually 50 % decrease or normalisation of liver enzymes, or survival rate in DILI-related ALF patients. Overall, 15 trials described the randomisation method, eight were double-blind (n = 672) and nine had sample size esti- mation (n = 880). Four RCTs involving 377 patients used an intention-to-treat analysis. Based on the scarce number of trials available, tested agents showed limited efficacy in DILI prevention and management and a favourable safety profile. In conclusion, heterogeneity among studies in DILI case qualification and methodologic quality was evident, and the RCTs performed demonstrated limited efficacy of specific interventions. Interna- tional research networks are needed to establish a framework on RCTs design and therapeutic endpoints.This work was supported by grants of Instituto de Salud Carlos III cofounded by Fondo Europeo de Desarrollo Regional - FEDER (contract numbers: PI18/00901; PI18/01804; PT17/0017/0020; PT 20/00127) and Agencia Espan ̃ola del Medicamento. Plataforma de Investigacio ́n Clínica and CIBERehd are funded by ISCIII. MRD holds a Joan Rodes (JR16/00015)/Accio ́n B clinicos investigadores (B-0002-2019), JSC a Rio Hortega (CM17/00243) and IAA a Sara Borrell (CD20/00083) research contract from ISCIII and Consejería de Salud de Andalucía. This publication is based upon work from COST Action “CA17112 - Pro- spective European Drug-Induced Liver Injury Network” supported by COST (European Cooperation in Science and Technology). www.cost.e

    A DNA Microarray-Based Assay to Detect Dual Infection with Two Dengue Virus Serotypes

    Get PDF
    Here; we have described and tested a microarray based-method for the screening of dengue virus (DENV) serotypes. This DNA microarray assay is specific and sensitive and can detect dual infections with two dengue virus serotypes and single-serotype infections. Other methodologies may underestimate samples containing more than one serotype. This technology can be used to discriminate between the four DENV serotypes. Single-stranded DNA targets were covalently attached to glass slides and hybridised with specific labelled probes. DENV isolates and dengue samples were used to evaluate microarray performance. Our results demonstrate that the probes hybridized specifically to DENV serotypes; with no detection of unspecific signals. This finding provides evidence that specific probes can effectively identify single and double infections in DENV samples

    NectarCAM : a camera for the medium size telescopes of the Cherenkov Telescope Array

    Full text link
    NectarCAM is a camera proposed for the medium-sized telescopes of the Cherenkov Telescope Array (CTA) covering the central energy range of ~100 GeV to ~30 TeV. It has a modular design and is based on the NECTAr chip, at the heart of which is a GHz sampling Switched Capacitor Array and a 12-bit Analog to Digital converter. The camera will be equipped with 265 7-photomultiplier modules, covering a field of view of 8 degrees. Each module includes the photomultiplier bases, high voltage supply, pre-amplifier, trigger, readout and Ethernet transceiver. The recorded events last between a few nanoseconds and tens of nanoseconds. The camera trigger will be flexible so as to minimize the read-out dead-time of the NECTAr chips. NectarCAM is designed to sustain a data rate of more than 4 kHz with less than 5\% dead time. The camera concept, the design and tests of the various subcomponents and results of thermal and electrical prototypes are presented. The design includes the mechanical structure, cooling of the electronics, read-out, clock distribution, slow control, data-acquisition, triggering, monitoring and services.Comment: In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.0589

    The Supersymmetric Particle Spectrum

    Full text link
    We examine the spectrum of supersymmetric particles predicted by grand unified theoretical (GUT) models where the electroweak symmetry breaking is accomplished radiatively. We evolve the soft supersymmetry breaking parameters according to the renormalization group equations (RGE). The minimization of the Higgs potential is conveniently described by means of tadpole diagrams. We present complete one-loop expressions for these minimization conditions, including contributions from the matter and the gauge sectors. We concentrate on the low tanβ\tan \beta fixed point region (that provides a natural explanation of a large top quark mass) for which we find solutions to the RGE satisfying both experimental bounds and fine-tuning criteria. We also find that the constraint from the consideration of the lightest supersymmetric particle as the dark matter of the universe is accommodated in much of parameter space where the lightest neutralino is predominantly gaugino. The supersymmetric mass spectrum displays correlations that are model-independent over much of the GUT parameter space.Comment: 62 pages + 10 PS figures included (uuencoded), MAD/PH/80

    The Sensitivity of HAWC to High-Mass Dark Matter Annihilations

    Full text link
    The High Altitude Water Cherenkov (HAWC) observatory is a wide field-of-view detector sensitive to gamma rays of 100 GeV to a few hundred TeV. Located in central Mexico at 19 degrees North latitude and 4100 m above sea level, HAWC will observe gamma rays and cosmic rays with an array of water Cherenkov detectors. The full HAWC array is scheduled to be operational in Spring 2015. In this paper, we study the HAWC sensitivity to the gamma-ray signatures of high-mass (multi- TeV) dark matter annihilation. The HAWC observatory will be sensitive to diverse searches for dark matter annihilation, including annihilation from extended dark matter sources, the diffuse gamma-ray emission from dark matter annihilation, and gamma-ray emission from non-luminous dark matter subhalos. Here we consider the HAWC sensitivity to a subset of these sources, including dwarf galaxies, the M31 galaxy, the Virgo cluster, and the Galactic center. We simulate the HAWC response to gamma rays from these sources in several well-motivated dark matter annihilation channels. If no gamma-ray excess is observed, we show the limits HAWC can place on the dark matter cross-section from these sources. In particular, in the case of dark matter annihilation into gauge bosons, HAWC will be able to detect a narrow range of dark matter masses to cross-sections below thermal. HAWC should also be sensitive to non-thermal cross-sections for masses up to nearly 1000 TeV. The constraints placed by HAWC on the dark matter cross-section from known sources should be competitive with current limits in the mass range where HAWC has similar sensitivity. HAWC can additionally explore higher dark matter masses than are currently constrained.Comment: 15 pages, 4 figures, version to be published in PR

    Hospital Virtual: Sistema de información clínica y telecuidado de pacientes VIH/SIDA basado en tecnologías Web 2.0

    Get PDF
    Este artículo describe el desarrollo de un nuevo sistema de información clínica y telecuidado de pacientes VIH/SIDA que se encuentra implantado en rutina clínica dentro del Servicio de Enfermedades Infecciosas del Hospital Clínic de Barcelona. El proyecto surge ante la necesidad de unificar el sistema de información departamental del servicio y un sistema de telemedicina instalado en el hospital en 2004. Para ello se han diseñado e implementado nuevas bases de datos y dos sistemas específicos para uso de profesionales y pacientes. Además, se ha realizado una integración con el Sistema de Información del Hospital (HIS) permitiendo el acceso a todos los datos requeridos de los pacientes desde una única aplicación. Este nuevo sistema está al servicio de más de 70 profesionales sanitarios que realizan una media de 150 consultas al día disponiendo de información clínica de más de 8000 pacientes
    corecore